Adult & Infant Training Test Lung

The Adult-Infant Training Test Lung and PneuView systems incorporate one adult lung and one infant lung simulator in a single unit. This provides great flexibility and range for demonstrations, testing, research, and training. As with all of our test lungs, the Adult-Infant model is available with or without PneuView electronics and software.
Additional information, including product features and specifications can be found below.
Note: All PneuView 3 Systems include a compatible laptop computer.
 

 

  • Specs

    PARAMETER MEASUREMENT RANGE ACCURACY
    Breath Rate* 2 to 1,100 bpm +/- 1 bpm
    Inspiratory/Expiratory Time* 0.3 to 30 sec +/- 0.03 sec
    Tidal Volume (Infant) 5 to 200 mL +/- 5% or 5 mL
     Tidal Volume (Adult) 0.1 to 2.0 L  +/- 3% or 20 mL
    Flow Rate* (Infant) 3 to 80 Lpm (3 to 30 Lpm) +/- 2 Lpm                                                                         (30 to 80 Lpm) +/- 4 Lpm
    Flow Rate* (Adult) 10 to 200 Lpm (10 to 60 Lpm) +/- 3 Lpm                                                               (60 to 200 Lpm) +/- 5 Lpm
    Pressure: (Lung/Airway) -20 to 120 cmH2O*                                 -10 to 120 cmH2O +/- 2%
    Pressure: (Auxilliary Port)* 0 to 100 psi +/- 5% of user-calibrated Full Scale Output (FSO)
    Compliance (Infant) .001 to .01 L/cmH2O +/- 3% (at calibration volumes)
    Compliance (Adult) .01 to 0.1 L/cmH2O  +/- 3% (at calibration volumes)
    Resistance Rp5, Rp20, Rp50 (Adult)           Rp50, Rp200, Rp500 (Infant) cmH2O/L/sec +/- 5% (at calibration flows)
    *-AI3 (PneuView) Model Only
  • Features

    Features of the Adult-Infant Training Test Lung and PneuView

    Adult-Infant Training Test Lung and PneuView units provide a range of simulations and are particularly useful for training, testing, and demonstration of devices and therapies intended for use across a wide range of patient populations.
    • Full range of lung compliance and airway resistance settings for both Adult and Infant simulators
    • Independent operation of the adult and infant lung speeds the testing, training, and demonstration process
    • Tidal volume capacity of 2.0 liters in the adult lung and 200 ml in the infant lung
    • Residual lung volume of 1.02 liters in the adult lung and 70 ml in the infant lung
    • Add an Adult or Infant Head Simulation Module for non-invasive ventilation and support applications
    • Access ports for additional monitoring or introduction of physiologic/therapeutic gases
    • The adult lung may be coupled to the infant lung and driven to simulate a spontaneous breathing infant patient
    (NOTE: Michigan Instruments does not recommend using the infant lung to lift the adult lung during spontaneous breathing simulations. Doing so may cause damage to the infant lung.)